Assessment of the diagnostic accuracy of 18F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria

  1. Jiménez-Ballvé, A. 1
  2. Pérez-Castejón, M.J. 1
  3. Delgado-Bolton, R.C. 12
  4. Sánchez-Enrique, C. 1
  5. Vilacosta, I. 1
  6. Vivas, D. 1
  7. Olmos, C. 1
  8. Ferrer, M.E.F. 1
  9. Carreras-Delgado, J.L. 1
  1. 1 Universidad Complutense de Madrid
    info

    Universidad Complutense de Madrid

    Madrid, España

    ROR 02p0gd045

  2. 2 Centro de Investigación Biomédica de La Rioja
    info

    Centro de Investigación Biomédica de La Rioja

    Logroño, España

    ROR https://ror.org/03vfjzd38

Revista:
European Journal of Nuclear Medicine and Molecular Imaging

ISSN: 1619-7070

Año de publicación: 2016

Volumen: 43

Número: 13

Páginas: 2401-2412

Tipo: Artículo

DOI: 10.1007/S00259-016-3463-9 SCOPUS: 2-s2.0-84994298851 WoS: WOS:000387478500017 GOOGLE SCHOLAR

Otras publicaciones en: European Journal of Nuclear Medicine and Molecular Imaging

Resumen

Purpose: The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of 18F-FDG PET/CT in these patients and analyse the interpretation criteria. Methods: We included 41 patients suspected of having IE by the Duke criteria who underwent 18F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. 18F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. Results: We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∆SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). Conclusion: The value of 18F-FDG PET/CT in the diagnosis of suspected IE of PVs and CIEDs is highly dependent on patient preparation and the method used for image interpretation. Based on our results, the best method is to consider a study positive for IE when FDG uptake is present in both AC PET and NAC PET images. © 2016, Springer-Verlag Berlin Heidelberg.